Replace a component used in a pattern component

$
0
0

Hi,

it's normal that on NX11 a component that creates a linear pattern component, if replaced, linear pattern components remain the old component?

Luckily it's associative pattern component. Pattern a phantom part number.

Absurd.

NX assembly environment is an environment that always leaves me speechless.But the commands you implement, test them / use.These are the basics.It's called associative CAD.


get minimum distance between two component from excel

$
0
0

Hello,

 

I have a list of many pairs of components in excel table, i want to get the minimum distance of those pairs of components in NX and put it back into the excel table

 

I am totally new to Macro, and i have no idea how to create this Macro

 

Please help me with the problem.

 

Thank you very much in advance!

Feature control frame PMI for hole callout

$
0
0

Is there is any way to add FCF pmi to hole callout?

I want to assign characteristices/ tolerances mentioned in FCF to all holes from pattern.

FCF should contain no of holes (e.g. 6X) for understanding.

See attached image.

Drafting template

$
0
0

Hi guys,

 

When I mark as template a drafting, some options should appear like :

  • Add symbols to region
  • Template Region

And to customize my template I would like to insert autonome view with a specific orientation. But I don't have the orientation setting.

 

Does some of you have an idea, license, setting something else ?

 

Thank you

 

Help from a Expression Guru - NX11

$
0
0

Dear all,

I hope someone can get me on the right track with some expression unskillfulness...

I want to drive a sketch, this limited by 2 Expression Lists and pending on a type of material

First Input:

(String) Material="Copper"
(List) Material_Options={"Copper"; "Graphite"}

Second input – 2 Lists of specific size for each Material:

(List) Copper_Electrode_data={{"10x30", "10x40", "10x50"}, {10, 10, 10}, {30, 40, 50}}

(List) Graphite_Electrode_data={{"15x15", "20x30", "20x40"}, {15, 20, 20}, {15, 30, 40}}


So far I have it working that the Electrode Size takes the List from Graphite_Electrode_data:

(String) Electrode_Size="20x40"
(List) Electrode_Size_Options=First(Graphite_Electrode_data)

What I would like to have is, that when Material is changed (to “Copper”), the Elektrode_Size takes the List from Copper_Electrode_data.
And offcourse how to to this?
Anybody any idea? Is the approach I have set up here ok?

Many thanks!

nx 11 zip assembly

$
0
0

Anyone know a way of zipping assemblies in nx11 besides cloning

UI: NX Theme, which one do you prefer

$
0
0

Hello,

 

I'm working with NX 19 Years ago. Since Unigraphics V15.
So I've seen some different UI's in all the time. Some things are now better, some not.

 

 

Which of the NX Thems for the UI do you prefer?

The pictures her are captured from NX1847.

 

NX_UI_Themes.png

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Since the "Light (Recommended)" is appeared much people work with them.

But I'm not satisfied with that. It has too little contrast, and anityhng is in white to light gray.
And with the Windows 10 (2 Dimensional?!?) design, it's much difficult to see where a window begins and ends.
 
NX_UI_Theme_Light.png
 
 
The "Light Gray" is'nt really an alternative for me. Looks as the same, but gray in gray.
 
NX_UI_Theme_Light-Gray.png
 
 
My Favorite: "Classic with System Fonts"
It gives good contrasts, particular in CAM menues.I see much more better where windofs begins and ends.
Why "with System Fonts? Well, the characters are a bit narrow, so there I can se more of them in the input fields.
Yes, I like it.
 
NX_UI_Theme_Classic-with-System-Font.png
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
An then the "System" theme. It looks not bad, but I don't like it. There are no lines in the ONT.
The only interresting thing is the red or blue arrows for collapsed/uncollapsed parts of menues.
 
NX_UI_Theme_System.png
 
 
Why am I talking here about that?
I'm afraid, in future the different themes will desappear. Then ther is only one unit theme and maybe
it's not my preferred theme.
 
What is your opinion?
 
 
 
Regards
TomS
 
 
 

NX Monthly Update (NX 1855) is available for download

$
0
0

Affected Software: NX 1847 SERIES
Scope: WINDOWS 64-BIT


Dear Siemens PLM Customer,


We are pleased to inform you that the latest product release of NX is now available for download from the Siemens PLM Download Server.

 

Download of NX on Windows 64-bit

Please use the following steps to download the NX product release and its documentation.
Note: A valid WebKey account is required.

• In your browser's address field enter the URL: https://download.industrysoftware.automation.siemens.com/
   Login using your WebKey username and password

• From the Download page, enter "SiemensNX-1855_wntx64" (including the quotes) in the Search field to return a list of links for the Release Letter and the Release Packages.

• Alternatively the NX product release can be found using file navigator by entering NX into the Product Filter feature on the left of your browser and then navigating through the NX directory structure as follows:
      o Expand the "NX" folder
      o Expand the "NX 1847 Series" folder
      o Expand the current release folder; "NX 1855"

 

 Screenshot - 3_14_2019 , 1_27_33 PM.png

 

To download the NX product:
      o Right click on the Release Package files
      o Select "Save Target As" or "Save Link As" to save the files to your local destination

 

• When an NX series is replaced by a newer version, the previous version (including its documentation) will be moved to the "NX Supported" folder within the "NX Support" folder. For example, NX 1851 can be downloaded as follows:
      o Expand the "NX Support" folder
      o Expand the "NX Supported" folder
      o Expand the "NX 1847 Series" folder
      o Expand the available release name; "NX 1851"

 

Screenshot - 3_14_2019 , 1_30_33 PM.png

 

NX 1847 follows this strategy and can be downloaded from the "NX 1847 Series" folder as shown below:

 

Screenshot - 3_14_2019 , 1_31_41 PM.png 

 

• Once NX has been installed, on-context help will point to the GTAC online documentation by default, so you only need to download the documentation if you want to install a local documentation server.

To download the NX documentation:      

      o Expand the "NX" folder
      o Expand the "NX 1847 Series" folder
      o Expand the "Documentation" folder
      o Right click on the product documentation link
      o Select "Save Target As" or "Save Link As" to save the file to your local destination.
      In all cases, please refer to the supplied README file for installation instructions.


If you encounter any problems during this installation, please contact your local Siemens PLM Software support office.

For current information about NX including News, Events, Case Studies, Software Updates and User Group activities please visit our website by selecting the following links:

• NX:  http://www.plm.automation.siemens.com/en_us/products/nx/
• GTAC:  http://support.industrysoftware.automation.siemens.com/gtac.shtml


Sincerely,

Ben Broad
Siemens Product Lifecycle Management Software Inc.
Digital Factory Division


Larger file size problem

$
0
0

Hi All,

Any ways to reduce file size in NX rather than heal geometry and part cleanup?

First I have imported STL model to spaceclaim and converted to solid then imported to NX in STP format which created the file size with 120MB .

I tried both heal geometry and part cleanup which reduced only 10MB.

It will be very helpful if anyone share their experience and the effective methods to deal with file size.

 

Regards,

Ravi

Wiring/Routing body in an assembly

$
0
0

After making a wiring spline and assigning stock to it,

The wiring body is visible.

 

- Where can I find this body in the assembly browser ??

- How can I make such body visible again after switching it un-visible ?

- Why do these bodies stay visible when switching the assembly un-visible ?

 

I am trying to get my mind around how this wiring behaves in an assembly .....

And trying to find ways of handling them.

 

Greez,

 

Mohammed

Count numer of holes in NX modeling enviroment.

$
0
0

Hi,

 

Is there any tool in NX modeling enviroment to count the number of holes automatically?

 If it exists, would it also works with an imported step file?

 

Using NX 11 and soon NX12

 

Thanks for your help

 

Jose Carlos

 

 

 

 

 

Revolved or Extruded body color from selected Section curve color

$
0
0

Hello Friends

 

I am working with Section Curves (From Edit Section) in a huge assembly. After generating the section curves i am changing the color of the curves.

 

If i revolved or extruded the Edit Section Section Curves the revolved body or extruded body should be generated with the color of the Section Curves. For example if the green color section curves are selected for revolve then the revolve body should also come in green color.

 

Is there any optio to set this.

 

thanks in advance

 

Sekar

Sweep Along Guide / Swept / Variational Sweep

$
0
0

I am trying to sweep a curve along the guide line and the body is intersecting itself creating a void.

 

Anys suggestions would be helpful.

I saw few tutorials on youtube but didn't help. Please redirect me to useful tutorials or a solution to overcome this. Thank you

 

Is clone assembly feature a glorified 'Save as'?

$
0
0

When would you ever have to use clone assembly? I guess with really large assemblies with a lot of parts you want to do a save as with. But maybe there's a more interesting use of this command?

 

And what is the difference between 'Create Clone Assembly' and 'Edit Existing Assembly' commands, they both have the same options. 

Highlight Selection on Rollover Default Setting

$
0
0

Does anyone know if there is a way to set the settings as default for the highlight selection on rollover to be off on installation and/or the time setting that delays the rollover highlighting?

I don't see any customer defaults for these settings.

 

2019-03-16_21-02-06.png

Thanks!

 


NX12 JT Export settings do not work

$
0
0

Hello,

 

in NX 11 I had no problems with the JT export.

In NX12 I see only wireframes and no bodies in the exportet JT-File. I couldn’t find any setting to change that (see). For this case I made a simple modle. The step203 export works. (see uploaded jt, prt, config, step)

 

Can you please help me?

 

JT2Go view.pngNX View.pngNX JT export settings in  model.png

Disable Wave link association without it updating first

$
0
0

Hello everyone,

I'm currently working on a teamcenter assembly which contains parts to which I don't have the rights to. I've made the mistake of creating associative links for the part that link to a part I don't have controll over. This part is a baseline for many other parts down the line. I don't quite know why, but whenever I load the part, the associated link somehow updates and moves the entire part somewhere else in the assembly.
Is there an easy way to disable the updates / break the link without it first doing its wonky updates or do I have to reconstruct everything down the line?

Thank you for your help.

How can i place the face on another face by copy the shape of the destination object

$
0
0

Imagine that if we want to attached the paper on the complex shape panel. 

Whcih function which i should do?

I try "replace face" but i dont want intersection line, i want only the rectangular of the original shape.

in case to do the simulation, and easy to get a good mesh

The application for this is damping layer attached to door panel.

 

How to fully evaluate a sketch to see whether it is closed or open, look for tiny gaps, etc?

$
0
0

How can I fully evaluate a sketch to see whether it is a closed or open profile, where there are tiny intersections or gaps or overlaps  that are hard to visually see, and how to identify reference lines?

 

And how do you create a reference line that is infinite? I should only have to define the location and orientation of the reference line, I shouldn't have to contrain it's length to fully contrain the sketch. 

Electrical Routing feature request

$
0
0

As simular issued in ER 8995552

 

Feature request for Electrical Routing Stock.

When selecting stock for electrical routing, there are several shortcomings:

- Selection is limmited to a list that is in a text file under the mechanical routing defaults.

- A color can only be applied afterards.

 

Request:

 

- Add the possibility for general stock to enter a custom size on selection (like with space reservation in the past)

- Add the possibility to choose a color on stock selection.

- Add the possibility to store your selection as a default stock under a costom name from the selection menu.

 

Reason:

When using electrical routing for cabling, one is confronted with a hudge variaty of diameters available for cabling.

Getting all diameters available in the stock defaults file requires a lot of work, where only a small part only will be used in the end.

Next to that, to do such editing, one has to dig deep into the program directory of NX to find the correct file. This is not desireable for the default user.

 

Br