0

Is there any way to save a file after recieving this message? If there is I haven't found a way. Please see the attached image. I have tried a "save as" and that fails as it's looking for the old part that was opened before another user opened the part on their machine and saved over the part.

This is a major problem with NX if you don't have TeamCenter PDM installed. Why is it that all Microsoft Windows Applications (word, excel, powerpoint, etc.) can recognize that another user has a file open and will automatically make a file read only for a second person that opens the file with a warning that states this to the second user, but Siemens can't do the same?!? This has happened a number of times in our operation and it is very costly time wise and money wise!

 


NX 10 Shortcut Icon is lost

$
0
0

Hi,

 

I have unpinned my NX 10 icon and now I cannot find it. So my question is where is the location that I can find the NX 10 icon so I can pin in back.

 

Thank you.

 

 

UG NAME and Component Name in NX managed mode

$
0
0

Hello

The documentation regarding BOMLine note synchronization does state that the following attributes are treated "Special" in Teamcenter / NX.

UG NAME, UG GEOMETRY, UG ENTITY HANDLE, UG ALTREP, UG REF SET.

 

For this discussion I would concentrate only on UG NAME and UG GEOMETRY.

The procedure to set this is through right-click on Component -> Properties. You can specify if this component is a non-geometric component with a check box which automatically sets UG GEOMETRY in the attributes section. We can also set Component Name in the general Tab which will automatically synchronize it to UG NAME note in Teamcenter. If you specify an instance attribute UG NAME using the attributes tab, this will not be picked up by the note in Teamcenter (It would still synchronize with the Component Name), but UG GEOMETRY would! I am willing to accept that this is some internal logic in Teamcenter / NX (Documentation is quite clear on how Teamcenter and NX manage this by matching the real attribute name etc.,)

The question is why would UG GEOMETRY instance attribute work (I can change this in the attributes tab) but not UG NAME?

 

Extending the discussion a little further, this is a problem while exporting JT files outside of Teamcenter from NX. If I have an explicit attribute UG NAME, JT translator would automatically pick it up without any changes to configuration file of JT Translator and it would have the value set using the attributes tab and not the component name. Also, JT translator would not export the component name. Now, while creating parts list on a drawing sheet we can access this component name using the special character $COMPONENT_NAME (There are several others...$AREA etc.,). Can I wire UG NAME instance attribute to $COMPONENT_NAME? (I am guessing this $attribute too will be something internal to NX)

 

Thanks and Regards

Balaji

Customized user interface

$
0
0

I am not familiar with NX, but is it possible to customize (minimize) the NX user interface/functionality in a way that NX is only to use as a easy to use 2D design tool?

NX 10.0.3 - Maintenance Pack 5 Announcement

$
0
0

Dear Siemens PLM NX Customer,

Maintenance Pack 5 for NX 10.0.3 is now available on the Siemens PLM Download Server.

NX 10.0.3 MP5 is an accumulation of fixes built for installation on top of Windows 64-Bit and Linux 64-Bit images of NX 10.0.3.

To select the release package(s) for your platform(s) click on the following link or enter the URL in your browser address window:

       https://download.industrysoftware.automation.siemens.com/download.php

Note: A valid WebKey account is required.

From the Full Product Download page, Enter “10.0.3.mp05” (including the quotes) in the Search box to see a list of links to the release letter and available release packages.

Alternatively, the release packages can be found in the file navigator by selecting the ‘NX’ button and then navigating through the directory structure by selecting "Product updates > Maintenance-packs > Nx10 >
platform]".

Sincerely,

Ben Broad

Siemens PLM Software

How could I restore Fonts?

$
0
0

I was working with some old NX files and then noticed when I create drawings the title block texts are all squares. Their fonts have changed to “Symbol” So I corrected them assigning a new font.

Now when I open newer files which I had created recently, all the texts including dimensions are squares. I believe somehow my default font type has disappeared (Couldn't find the default font= Arial Unicode MS) and it has changed to “Symbol” type.

Is there a way to restore my Fonts?

Siemens Automation

$
0
0

What is Siemens Autmation? How it works and beneficial to us?

 

 

Thanks,

APS

Wavelink geometry linked feature looses associativity after replace component

$
0
0

Hi All,

I am trying to create an Assembly structure shown below using wavelinks.

 

- Assembly

   - Wavelinked geo

   - Finish Geo

   - Rough Geo

 

I have named the features with certain tags or feature name in Finish Geo.prt file and Rough Geo.prt. I have wavelinked these features in wavelinked geo.prt.

Now I try to replace the finish geo.prt with a similar prt file with same tag names. After doing this I find that the links in wavelinked geo.prt is broken.

I know I can replace the features manually. But we have close to 40 to 50 such linked features. Is there a possibility that NX reads the feature names and keep the links intact? Or am I doing something wrong..

Thanks


Studio Spline randomly starting

$
0
0

Hey everyone. I have a user creating manufacturing items in NX 9.0.2.5. While he is working the Studio Spline dialog box keeps popping up. The user is doing nothing to make this happen. I have spoken with GTAC a few times and tried all of their suggestions. This issue is not part specific. It is user specific however. Just wondering if anyone else has experienced this issue, and if so, what did you do to fix it?

Ordinate dimension datum symbol - it's gone oval!

$
0
0

Haven't seen this before - one of the users put down an ordinate dimension (something we do a lot), and the datum symbol is oval instead of round.  I can't see a way to modify the shape / aspect ratio in the settings dialogue.  For now he has hidden the symbol and placed a user-defined symbol in it's place, but this is non-associative and a rather nasty work-around.

 

Any ideas?

Protect Datum CSYS - NX9

$
0
0

Is it possible to protect a Datum CSYS entity?

 

For example we have a start component that has a datum CSYS which is used for assembly constraints and we want to make sure that the datum CSYS cannot be deleted.  Changing it to visible only is not a solution as designers have made it selectable and then end up deleting it by accident.

 

 

Thank you,

Duane - NX9.0.3.4

Clearance Analysis NX10

$
0
0

This is my first post here so I am not familiar with all the rules and I don't know if it's ok to mention other CAD programs.

 

I've recently exported an assembly file from Autodesk, where no interferences were found, to a STEP file so I could run simulations on it in NX10. While creating the mesh, I've noticed that I couldn't properly mate all the parts' meshes so I ran a Clearance Analysis. It turns out that almost every part was interfering with each other, because the cylindrical joints were being approximated with Polyhedrons and, therefore, since the parts were all tighly connected in the Autodesk file, they had interferences in the STEP file in NX10.

Is there any way around this? I can't edit all the parts so I was wondering if there was a way to add a margin so that the meshes in these parts surfaces could merge.

 

I attached the .prt files created from the .stp by NX. The assembly file is  FinalCadeiraTap_structural_stp

 

Thank you in advance,

Loismen

Model component hidden on new drawing

$
0
0

NX9 TC 10, using master model.

 

We have two sets of drawing formats, a set for NC, and a set for Indy.  If you create a model file, and then go file, new, and pick an Indy format, the model component comes in hidden.

ComponentHidden.jpg

If I do the exact same thing, but use one of the NC drawing formats, it is not hidden.  This seems to have started around January of this year, and I have no idea what may have triggered the change.  The only glaring difference I see, is that the Indy formats still use a "dummy part" in them to transfer attributes from the model to the drawing.  For the NC formats, I reworked them to use "DB_DWG_TEMPLATE_” , and got rid of the dummy file.  Note, the dummy part is not hidden in the drawing templates.

 

For the most part, they manage their own drawing templates, but I have been asked to figure out why the model component is being added as hidden.

 

Any thoughts?

Intel HD 520

$
0
0

Hello all first time on the forums. I am a Mechanical Engineering Technology student and was recently given a Lenovo x1 yoga. It is a nice laptop and was a gift from a family member. I asked for a nice laptop and this is what I received. The only issue is it has teh new Intel HD 520 graphics, not dedicated graphics. I know in recent years Siemens has began to support Intel HD graphics  and was wondering if anyone knew of plans to support the 520  integrated graphics? If not does anyone now how to get the best performance out of the Intel HD 520 graphics?

I may have to sell it and find something more my suited for CAD. Any advice would be great. Best regards.

Hello Community

$
0
0

Hello Community,

My name is Danijel.

After more than 10 years of working in CAD design with softwares such as ProE,Solidworks, Inventor...I would like to move on NX. Is it possible to get trial version of NX?

I appologize if I posted a topic on the wrong place of the community.

 

Best regards

Danijel


Hide_Feature_In_Drafting_View

$
0
0

Hello Guys,

                      I have a query in NX Drafting,

                      is there any option in nx to hide Feature detail.

                      I Used the suppress feature but after supress, next dependable feature also disabled.

 

For Example:- I attached a pulley drawing image, in this i wanna Hide Feature & get Multiple Front View in Drafting for detail dimension,

 

1. With Pulley Teeth

2.Without Pulley Teeth 

Because i have to hide Pulley teeths , so i can see the detail like slot , hole etc.

 

So How to get two view with & Without Teeth In Drafting.......Pulley_7.JPG

 

 

 

Punch a text in sheet metal enviroment

$
0
0

Hello,

 

I have not to much experience in Sheet metal Enviroment and I need some help. How can I to punch a text into a sheet of metal?  I've used  text command following with insert/punch/bead.

It apears an error: "sectionshould not contain aBsplinecurvewithsharp corners"

Thanks for your help.

Jose C

Tolerance analysis for parts assembled -NX10

$
0
0

Hi Experts!,

I have been delivered a Transition Training for a customer

and as a result some questions were done.

One of this questions is related to which NX tool have to be use to analized

assembled tolerance parts.

A participant comment me that in the past this kind of analysis was done through PMI

and want to know if now we have to use any other NX tool.

I do not know if it is possible do same as with Clearance Analysis but I am afraid this Clearance Analysis

do not cover Tolerance and with PMI I do not know how to do to get tolerance analysis.

Do You know how to proceed? Are there any document that clearly explain the whole process to do this?

 

Thanks in advanced for your help...

 

Fidel

Looking for 3D model for conversion tests

$
0
0

Have someone a 3D model that can be shared?

I have to do some conversions test from NX to PC-DMIS and the .prt file should contain (at least)

- 3D model

- PMI features about

         - GD&T

         - roughness

         - tolerances on linear and diametral (radial?) dimension

 

Thank you

Change Language NX10

$
0
0

Hello,

 

I just installed NX10.0 in Spanish Language and I want to know how I can change it to English language when I need it and vice versa.

 

Thanks

 

Jose C.