Edge tolerance value

$
0
0

hello guys,

 

I have few questions how the edge tolerance is decided for the feature which is being obtained after series of operations.

 

For instance, I have a sketch, which is used for trim sheet (tolerance is set to 0.0005 in trim sheet UI). after performing it, I'm thickening the sheet (tolerance is set to 0.0001 in trim sheet UI).

I was hoping the tolerance of the resultant feature would be 0.0006 (Cumulative tolerance), instead the information window had shown the result as 0.00055.

 

Could anyone explain the methodolody behind this calculation. (When series of operations are used)

 

thanks in advance

 